log(M)

STRERR(ADM)


     STRERR(ADM)                        UNIX System V



     Name
          strerr - STREAMS error logger daemon


     Syntax
          strerr


     Description
          strerr receives error log  messages  from  the  STREAMS  log
          driver  [log(M)]  and appends them to a log file.  The error
          log files produced reside in the directory /usr/adm/streams,
          and  are  named error.mm-dd, where mm is the month and dd is
          the day of the messages contained in each log file.

          The format of an error log message is:

          <seq> <time> <ticks> <flags> <mid> <sid> <text>

               <seq>     error sequence number

               <time>    time of message in hh:mm:ss

               <ticks>   time of message in machine ticks  since  boot
                         priority level

               <flags>   T : the message was also sent  to  a  tracing
                         process
                         F : indicates a fatal error
                         N : send mail to the system administrator

               <mid>     module id number of source

               <sid>     sub-id number of source

               <text>    formatted text of the error message

          Messages that appear in the error log are intended to report
          exceptional  conditions  that  require  the attention of the
          system administrator.  Those  messages  which  indicate  the
          total  failure of a STREAMS driver or module should have the
          F  flag  set.   Those  messages  requiring   the   immediate
          attention  of  the  administrator  will have the N flag set,
          which causes the error logger to send  the  message  to  the
          system   administrator  via  mail(C).   The  priority  level
          usually has no meaning  in  the  error  log  but  will  have
          meaning if the message is also sent to a tracer process.

          Once  initiated,  strerr  will  continue  to  execute  until
          terminated  by the user.  Commonly, strerr would be executed
          asynchronously.


     Notes
          Only one strerr process at a time is permitted to  open  the
          STREAMS log driver.

          If a module or driver is generating a large number of  error
          messages,  running the error logger will cause a degradation
          in STREAMS performance.  If a large burst  of  messages  are
          generated in a short time, the log driver may not be able to
          deliver some of the messages.  This situation  is  indicated
          by gaps in the sequence numbering of the messages in the log
          files.


     Files
          /usr/adm/streams/error.mm-dd


     See Also
          log(M), STREAMS Programmer's Guide


     (printed 8/23/89)                                  STRERR(ADM)

Typewritten Software • bear@typewritten.org • Edmonds, WA 98026